Mouse Total MMP-9 | ||||||||||||||||||||||||||||
Mouse Total MMP-9 Quantikine ELISA Kit Summary
Product Summary The Quantikine Mouse MMP-9 (total) Immunoassay is a 4.5 hour solid-phase ELISA designed to measure total mouse MMP-9 (pro-, active, and TIMP-complexed MMP-9) in cell culture supernates, serum, and plasma. It contains NS0-expressed recombinant mouse MMP-9 and antibodies raised against the recombinant factor. Natural mouse MMP-9 showed dose-response curves that were parallel to the standard curves obtained using the recombinant Quantikine kit standards. These results indicate that this kit can be used to determine relative levels of natural mouse MMP-9. Preparation and Storage
Background: MMP-9The matrix metalloproteinases (MMPs) consist of 24 known human zinc proteases with essential roles in breaking down components of the extracellular matrix (ECM). Additional MMP substrates include cytokines, chemokines, growth factors and binding proteins, cell/cell adhesion molecules, and other proteinases. With a few exceptions, MMPs share common structural motifs including a pro-peptide domain, a catalytic domain, a hinge region, and a hemopexin-like domain. Synthesized as pro-enzymes, most MMPs are secreted before conversion to their active form. MMP activities are modulated on several levels including transcription, pro-enzyme activation, or by their endogenous inhibitors, tissue inhibitors of metalloproteinases (TIMPs). A subset of MMPs are associated with membranes and designated as membrane-type metalloproteinases (MT-MMP).
Assay Procedure Refer to the product datasheet for the complete assay procedure. Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. 1. Prepare all reagents, standard dilutions, and samples as directed in the product insert. 2. Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal. 3. Add 50 μL of Assay Diluent to each well. 4. Add 50 μL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 2 hours. 5. Aspirate each well and wash, repeating the process 4 times for a total of 5 washes. 6. Add 100 μL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours. 7. Aspirate and wash 5 times. 8. Add 100 μL Substrate Solution to each well. 9. Add 100 μL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm. |
||||||||||||||||||||||||||||
上一篇:Human E-Cadherin 下一篇:Human L-Selectin/CD6 |