产品信息 >> 试剂盒相关 >> ELISA 试剂盒;
Human CD30/TNFRSF8

Human CD30/TNFRSF8 DuoSet ELISA Summary

Assay   Type

Solid   Phase Sandwich ELISA

Format

96-well   strip plate

Assay   Length

4.5   hours

Sample   Type & Volume Required Per Well

100 μL

Sensitivity

0.053   ng/mL

Assay   Range

93.8 -   6,000 pg/mL

Specificity

Natural and recombinant CD30/TNFRSF8

Cross-reactivity

<   0.5% cross-reactivity observed with available related molecules.< 50%   cross-species reactivity observed with species tested

Interference

No   significant interference observed with available related molecules.

Product Summary

This DuoSet ELISA Development kit contains the basic components required for the development of sandwich ELISAs to measure natural and Recombinant . The suggested diluent is suitable for the analysis of most cell culture supernate samples. Diluents for complex matrices, such as serum and plasma, should be evaluated prior to use in this DuoSet.

Preparation and Storage

Shipping

The   product is shipped at ambient temperature. Upon receipt, store it immediately   at the temperature recommended below.

Storage

Store   the unopened product at 2 - 8 °C. Do not use past expiration date.

Background: CD30/TNFRSF8

CD30/TNFRSF8 is a type I transmembrane glycoprotein belonging to the TNF receptor superfamily. The ligand for CD30 is CD30 Ligand/TNFSF8 (CD153), a member of the TNF superfamily. CD30 ligation by CD30 Ligand mediates pleiotropic effects, including cell proliferation, activation, differentiation and apoptosis.

Long   Name:

Lymphocyte   activation antigen CD30

Entrez   Gene IDs:

943   (Human); 21941 (Mouse); 25069 (Rat)

Alternate   Names:

CD30   antigen; CD30; CD30KI-1; CD30L receptor; cytokine receptor CD30; D1S166EKi-1;   Ki-1 antigen; Lymphocyte activation antigen CD30; TNFRSF8; tumor necrosis   factor receptor superfamily member 8; tumor necrosis factor receptor   superfamily, member 8

Assay Procedure

Refer to the product datasheet for the complete assay procedure.

Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.

1Prepare all reagents, standard dilutions, and samples as directed in the product insert.

2Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal.

3Add 50 μL of Assay Diluent to each well.

4Add 50 μL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 2 hours.

5Aspirate each well and wash, repeating the process 4 times for a total of 5 washes.

6Add 100 μL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours.

7Aspirate and wash 5 times.

8Add 100 μL Substrate Solution to each well.

9Add 100 μL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm.

上一篇:Mouse Total MMP-3
下一篇:Human Butyrylcholine
关于我们 | 产品信息 | 技术服务 | 联系我们

     电话:400-832-8698    地址:北京怀柔雁栖开发区光织谷东区二号楼 

   备案/许可证编号京ICP备2020036913号