Human MICA DuoSet ELISA Summary Assay Type | Solid Phase Sandwich ELISA | Format | 96-well strip plate | Assay Length | 4.5 hours | Sample Type & Volume Required Per Well | 100 μL | Sensitivity | 21.3 pg/mL | Assay Range | 62.5 - 4,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Saliva) | Specificity | Natural and recombinant human MICA | Cross-reactivity | < 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested | Interference | No significant interference observed with available related molecules. |
Product Summary This DuoSet ELISA Development kit contains the basic components required for the development of sandwich ELISAs to measure natural and recombinant human MICA. The suggested diluent is suitable for the analysis of most cell culture supernate samples. Diluents for complex matrices, such as serum and plasma, should be evaluated prior to use in this DuoSet. Preparation and Storage Shipping | The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below. | Storage | Store the unopened product at 2 - 8 °C. Do not use past expiration date. |
Background: MICAMHC class I chain-related genes MICA and MICB are transmembrane glycoproteins that function as ligands for human NKG2D. The two proteins are highly related, sharing 85% amino acid identity, but are also polymorphic. Recognition of MICA or MICB by NKG2D results in the activation of NK cell cytolytic activity and/or cytokine production. MICA/B are minimally expressed on normal cells, but are frequently expressed on or shed from epithelial tumors and can be induced by bacterial and viral infections. MICA and MICB recognition is involved in tumor surveillance, viral infections, and autoimmune diseases. Long Name: | MHC Class I-related Protein A | Entrez Gene IDs: | 100507436 (Human) | Alternate Names: | FLJ60820; MGC111087; MICA; PERB11.1 |
Assay Procedure Refer to the product datasheet for the complete assay procedure. Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. 1. Prepare all reagents, standard dilutions, and samples as directed in the product insert. 2. Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal. 3. Add 50 μL of Assay Diluent to each well. 4. Add 50 μL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 2 hours. 5. Aspirate each well and wash, repeating the process 4 times for a total of 5 washes. 6. Add 100 μL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours. 7. Aspirate and wash 5 times. 8. Add 100 μL Substrate Solution to each well. 9. Add 100 μL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm. |